Laboratory Instrument
and
supplies
เครื่องมือและอุปกรณ์ทางห้องแล็ป
สนใจรายละเอียดเพิ่มเติม
กรุณาแจ้งให้ทึมงานเพื่อ
จัดเตรียมหาสาระให้

Contact :
ติดต่อ
vichai-cd@usa.net
ชมรมเรารักสุขภาพ

We subscribe to the
HONcode principle of
the Health on the
Net Foundation
|
TC-84 is a compact,
user friendly,
computer-controlled spectrophoto-
meter, system features ;
|
UV
capability
|
| Bichromatic
operation |
Glycohemoglobin
test : Calculates
results automatically in % Glycohemoglobin |
|
Cardiac
risk calculation : Automatically
calculates VLDL, LDL fractions, %HDL
LDL/HDL ratio and assigns a risk factor.
|
|
37 C
incubating block
|
TC-84
is programmed to perform the
following 42 tests and provides 30
open channels for user tests.
| Test
No. |
Test
Name |
| 1 |
ACID
PHOSPHATASE |
| 2 |
ALBUMIN |
| 3 |
ALK.PHOSPHATASE
(kinetic) |
| 4 |
ALK.PHOSPHATASE
(color) |
| 5 |
ALT(SGPT)
kinetic |
| 6 |
ALT(SGPT)
color |
| 7 |
AMYLASE
kinetic |
| 8 |
AST(SGOT)
kinetic |
| 9 |
AST(SGOT)
color |
| 10 |
BILIRUBIN
direct |
| 11 |
BILIRUBIN
total |
| 12 |
BUN
kinetic |
| 13 |
BUN
color |
| 14 |
CALCIUM |
| 15 |
CARDIAC
RISK |
| 16 |
CHLORIDE |
| 17 |
CHOLESTEROL |
| 18 |
CK(CPK)
kinetic |
| 19 |
CK-MB |
| 20 |
CO2
340 nm. |
| 21 |
CREATININE
kinetic |
| 22 |
HEMOGLOBIN |
| 23 |
GAMMA
GT |
| 24 |
GLUCOSE
hexokinase |
| 25 |
GLUCOSE
oxidase |
| 26 |
GLYCOHEMOGLOBIN |
| 27 |
HDL
CHOLESTEROL |
| 28 |
IRON,
TOTAL |
| 29 |
LDH |
| 30 |
LIPASE |
| 31 |
MAGNESIUM |
| 32 |
PHOSPHORUS
, UV |
| 33 |
POTUSSIUM |
| 34 |
PROTEIN,
TOTAL |
| 35 |
SODIUM |
| 36 |
TRIGLYCERIDE,
GPO |
| 37 |
URIC
ACID |
| 38 |
TRIGLYCERIDE,
INT |
| 39 |
UIBC |
| 40 |
T3 |
| 41 |
T4 |
| 42 |
TSH |
| |
|
TECO
DIAGNOSTICS
California 92672, USA
| รายละเอียด |
ราคาต่อหน่วย
บาท |
เครื่องวัดเทียบสี
ระบบควบคุม
ด้วยคอมพิวเตอร์ม มี printer
Dry thermal block ในตัว
น้ำยาต่ำสุด 1 ml.
วัดได้ทั้งระบบ
End point, Kinetic , ใช้ได้
กับน้ำยา chem ทั่วไปได้ |
120,000.00
/
ชุด |
|
|
INSTRUMENT SPECIFICATIONS
| Linear
measurement range |
| 0.00
to 2.50 Absorbance units (A) |
| Photometric
accuracy |
+/-
(1% of the reading + 0.005 A) at 1.5 A
+/- (2% of the reading
+ 0.005 A) at 1.5-2 A |
| Stability
: |
drift
of no more than 0.005A in 8 hours/
bichromatic |
| Light
source : |
| tungsten
Halogen lamp |
| Wavelengths |
| 340
/ 405 / 450 / 505 / 550 / 600 nm. |
| Typical
half bandpass : |
| 10
nm |
| Type
of filter |
| Multiple
cavity sealed interference |
| Tube
size : |
| 12
mm Round standard |
| Minimum
fill volumn : |
| 1
ml. |
| Maximum
fill volumn : |
| 2
ml. |
| Temperature
: |
37
C (+/- 0.3), Block stay on, Cell has on/off
switch |
| Warm
up times : |
lamp
in Rate mode : 120 sec. built in
lamp in other mode : 45 seconds, built in
cell : 20-30 minutes, dependent on
ambient temperature
Incubation block : 20-30 minutes dependent
on ambient temperature |
| Lamp
sever time : |
| After
15 minutes idle, |
| Speed
: |
reads,
calculates and prints results in 3
seconds |
| Display
: |
| Alphanumeric,
16 character, red LED |
| Printer
: |
| Thermal,
dot matrix, 20 characters per line |
| Keyboard
: |
| 16
key, membrane switch, 4x4 audible resp. |
| Calculation
modes : |
single
point calibration by standard or factor
multipoint calibration with point to point curve
fit, multipoint percent absorbance, rate by
standard or factor (batch or single), fixed
time kinetic. |
| Power
requirements : |
120
V or 240 V AC, 50-60 Hz (switch
selectable |
| Dimensions
: |
9.5
x 13.25 x 3.75 inches or
24 x 34 x 10 cm |
| Weight
: |
| approx
10 lbs or 4.5 Kg. |
Recommended
operating
temperature : |
| 18
- 35 C |
| Recommended
operating humidity : |
| less
than 85 % |
| |
|
|